Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL |
NES-100-5 |
NES-100-12 |
NES-100-15 |
NES-100-24 |
NES-100-48 |
DC VOLTAGE |
5V |
12V |
15V |
24V |
48V |
CURRENT RANGE |
0 ~ 20A |
0 ~ 8.5A |
0 ~ 7A |
0 ~ 4.5A |
0 ~ 2.3A |
EFFICIENCY |
80% |
83% |
84% |
86% |
86% |
WAVE & NOISE |
80mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
ADJUSTABLE RANGE FOR DC VO;LTAGE | ±10% |
±10% |
±10% |
±10% |
±10% |
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION |
±1% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
SETUP, RISE HOLD UP TIME |
800ms, 60ms,50ms/230VAC at full load |
||||
VOLTAGE RANGE |
90~132VAC/180~264VAC by switch 254~370VDC |
||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||
IMPACT CURRENT |
Cold start current 45A/230VAC |
||||
WORKING TEMP. |
-10 ~ +50ºC |
||||
OVERLOAD PROTECTION |
105%-160% cut off the output , automatic recovery |
||||
OVER VOLTAGE PROTECTION |
115%-135%shunt down O/P voltage,re-power on to recover |
||||
WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC/100M Ohms |
||||
DIMENSION |
195*98*38mm (L*W*H) |
||||
WERIGHT |
0.55kg |
||||
PACKING |
34*32*24cm/30pcs/17kg |
||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. |
1. Prompt reply: Any inquiry or questions would be replied within 24 hours. |
2. Quality Product: Manufacture company, each of the products is tested and calibrated. |
3. Hospitality: Offer smiling service and your visiting is highly welcomed |
4. Fast delivery: delivery time is within 3-7 days usually, other occasion depends on the order qty. |
Trade Terms | FOB,CIF,CFR,EXW, |
Payment terms | T/T,L/C,Western union,Paypal,Escrow,MoneyGram |
Payment conditions | 30% deposit in advance,70% balance before shipping. |
Delivery time | 3-7working days after deposit,2-4 working days for inventory |
Packing | Neutral carton,Wooden case for large size |
Shipping | By sea,by air and by express delivery |
Payment conditions | 30% deposit in advance,70% balance before shipping. |
Delivery time | 3-7working days after deposit,2-4 working days for inventory |
Packing | Neutral carton,Wooden case for large size |
Shipping | By sea,by air and by express delivery |