Soft starting device is the high voltage ac motor starting equipment, its main composition is connected into the power between
the charged with motor and three instead of parallel thyristor components and electronic control unit. WSTRHV series high voltage
solid-state soft starting device is composed of multiple thyristor series parallel, by controlling the thyristor trigger Angle to control
the size of the output voltage, can satisfy the motor starting process in different voltage and current requirements. In the process
of motor starting, WSTRHV series high voltage solid soft starting device according to the preset curve starting, increase the voltage
of the motor, the motor smooth acceleration, so as to reduce motor starting on the grid, and connected equipment electrical and
mechanical shock. When the motor starts up to normal speed, the bypass vacuum contactor or circuit breaker is connected, and
the motor starts to finish. During the operation of the motor, the soft starting device continues to monitor the motor, measuring the
electric current, voltage and all kinds of fault protection in real time.
Category
|
Explanation
|
AC voltage
|
AC3kV/6kV/10kV,±10%-15%
|
Load type
|
Three - phase high - voltage AC induction motor, synchronous
|
Frequency
|
50Hz/60Hz ± 2Hz
|
Main circuit composition
|
3kV,12SCRS;6kV,18SCRS;10kV,30SCRS
|
Transient overvoltage protection
|
Pressure protection and resistance absorption network
|
Cooling method
|
Natural cooling
|
Control method
|
Three-wire
|
Environmental conditions
|
Ambient temperature: -10-40 deg.] C, altitude: not more than 2000 m, the relative humidity: not more than 85%
|
When the soft start device detects the external start command, after the microprocessor detects the synchronization signal, the main circuit thyristor
phase angle trigger control, and gradually increase the motor side of the current and voltage, so smooth start the motor. In this process, the RC RC
absorber absorbs the peak voltage at the time of thyristor reverse turn-off; the voltage-controlled thyristor voltage ensures that each thyristor voltage
in the series circuit is equal. Fiber triggering ensures electrical isolation between the controller and the high voltage thyristor, while ensuring that the
trigger signal is not subject to electromagnetic interference.
1. Protection function
2. Measurement functions
3. Communication Interface
4. Open and out
5. The user interface
Model
|
Voltage level
|
Rated current
|
Cabinet size
|
||
(kV)
|
(A)
|
H(mm)
|
W(mm)
|
D(mm)
|
|
WSTRHV-350/3
|
3
|
80
|
2300
|
1000
|
1500
|
WSTRHV-650/3
|
3
|
160
|
2300
|
1000
|
1500
|
WSTRHV-900/3
|
3
|
220
|
2300
|
1250
|
1500
|
WSTRHV-1150/3
|
3
|
280
|
2300
|
1250
|
1500
|
WSTRHV-1500/3
|
3
|
360
|
2300
|
1250
|
1500
|
WSTRHV-1500(the above)
|
3
|
>360
|
Booked
|
||
WSTRHV-700/6
|
6
|
80
|
2300
|
1000
|
1500
|
WSTRHV-1300/6
|
6
|
160
|
2300
|
1000
|
1500
|
WSTRHV-1800/6
|
6
|
220
|
2300
|
1000
|
1500
|
WSTRHV-2300/6
|
6
|
280
|
2300
|
1000
|
1500
|
WSTRHV-3150/6
|
6
|
360
|
2300
|
1000
|
1500
|
WSTRHV-3000/6(the above)
|
6
|
>360
|
Booked
|
||
WSTRHV-850/10
|
10
|
60
|
2300
|
1000
|
1500
|
WSTRHV-1100/10
|
10
|
80
|
2300
|
1000
|
1500
|
WSTRHV-2000/10
|
10
|
140
|
2300
|
1000
|
1500
|
WSTRHV-2200/10
|
10
|
160
|
2300
|
1000
|
1500
|
WSTRHV-2750/10
|
10
|
200
|
2300
|
1000
|
1500
|
WSTRHV-3050/10
|
10
|
220
|
2300
|
1000
|
1500
|
WSTRHV-3800/10
|
10
|
280
|
2300
|
1000
|
1500
|
WSTRHV-5000/10
|
10
|
360
|
2300
|
1000
|
1500
|
WSTRHV-5000/3(the above)
|
10
|
>360
|
Booked
|