Customization: | Available |
---|---|
Type: | SPD Surge Protective Device |
Structure: | Protective Gap |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model |
LY1-D | |||
Technical Parameters | ||||
Rate Operating Voltage Uc(V~) | 220V | 380V | 220V | 380V |
Maximum Continuous Operating Voltage Uc(V~) | 275V | 385V | 320V | 385V |
Voltage Protection Level Up(V~)kA | ≤0.7 | ≤1.0 | ≤1.2 | ≤1.5 |
Nominal Discharge Current In(8/μ20μs)kA | 5 | 10 | ||
Maximum Discharge Current Imax(8/μ20μs)kA | 10 | 20 | ||
Response Time ns | <25 | |||
Test Standard | GB18802.1\IEC61643-1 | |||
L/N(mm2)The Cross Section of L/N Line | 6 | |||
PE(mm2)The Cross Section of PE Line | 16 | |||
Fuse or Switch(A) | 10A,16A | 16A,25A | ||
Operating Environment°C | -40°C~+85°C | |||
Relative Humidity(25°C) | ≤95% | |||
Installation | Standard Rail 35mm | |||
Material Of Outer Covering | Fiber glass reinforced plastic |
Technical parameters | LY1-C | N-PE | |||||||||||
Rated operating voltage Un | 110V | 220V | 380V | 220V | 380V | 220V | 380V | ||||||
Max continuous operating voltage Uc | 140V | 275V | 320V | 385V | 420V | 440V | 275V | 320V | 385V | 420V | 440V | 255V | |
Voltage protection level Up | <=0.8 | <=1.2 | <=1.5 | <=1.8 | <=2.0 | <=1.2 | <=1.0 | <=1.4 | <=1.5 | <=1.8 | <=2.0 | <=1.0/<=1.0/<=1.8 | |
Normal discharge current In | 20kA | 15kA | 5kA/12.5kA/25kA | ||||||||||
Max discharge current Imax | 40kA | 30kA | |||||||||||
Response time | <25ns | 100ns | |||||||||||
Test standard | GB18802,IEC61643-1 | ||||||||||||
The cross section of L/N line | 10,16mm2 | 10mm2 | |||||||||||
The cross section of PE line | 10,25mm2 | 16mm2 | |||||||||||
Fuse or Switch | 32A | 25A,32A | |||||||||||
Operating environment | -40~+85 degrees | ||||||||||||
Relative humidity | <=95% | ||||||||||||
Installation | Standard rail 35mm | ||||||||||||
Material of outer covering | Fiber glass reinforced plastic |
Technical parameters | LY1-B | |||||
Rated operating voltage Un | 220V | 380V | 220V | 380V | 220V | 380V |
Max continuous operating voltage Uc | 385V | 420V | 385V | 420V | 385V | 420V |
Voltage protection level Up | <=2.8 | <=3.2 | <=2.2 | <=2.5 | <=2.0 | <=2.3 |
Normal discharge current In | 60kA | 40kA | 30kA | |||
Max discharge current Imax | 100kA | 80kA | 60kA | |||
Response time | <25ns | |||||
Test standard | GB18802,IEC61643-1 | |||||
The cross section of L/N line | 16,25mm2 | 10,16mm2 | 10,16mm2 | |||
The cross section of PE line | 25,35mm2 | 25mm2 | 16,25mm2 | |||
Fuse or Switch | 63,100A | 63A | 32,63A | |||
Operating environment | -40~+85 degrees | |||||
Relative humidity | <=95% | |||||
Installation | Standard rail 35mm | |||||