• 63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
  • 63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
  • 63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
  • 63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
  • 63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
  • 63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay

63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: None
Installation: Fixed
Structure: MCB
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
WD-B63
Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CE
Rated Operating Current
10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Display
Digital
Rated Voltage
230V50Hz
Recovery Delay Time
2s-512s (Default 60s)
Delay Time for Power-on
2s-255s (Default 2s)
Transport Package
Inner Box+Outer Carton
Specification
86*36*66mm
Trademark
Winston/OEM/Neutral
Origin
China, Zhejiang, Wenzhou
Production Capacity
20000PCS/Month

Product Description

Adjustable Intelligent digital Overv and Under voltage Protection device stabilizers with over voltage protector

voltage regulator stabilizer

I. Purpose

   Intelligent over-/under-voltage limit current protector is a comprehensive intelligent protector thatintegrates over-
current protection, over-voltage protection, under-voltage protection, voltagemeasurement, voltage display, current
measurement and current display protection functions. In theevent of overcurrent fault or overvoltage fault or
undervoltage fault, the protector can cut off thepower supply instantaneously and protect the electrical equipment
from being burned out. When theline returns to normal, the protector can automatically restore power. The overcurrent
value, overvoltage value,overvoltage recovery value, undervoltage value, undervoltage recovery value, operation time,
recovery time and power-on time of the product can be set by themselves, as well asfault memory and fault inquiry
functions and restore factory settings.The real-time voltage value andcurrent value are displayed cyclically. Each time
you press the  button, you can select the voltage orcurrent to be displayed separately. Press the  button to resume
the rotation display. It is easy to useand flexible, and can be used as a voltmeter or ammeter. Users can choose the
appropriate categoryof protectors according to the actual situation.

II. Main technical parameters

Product model

WD-B63

Rated voltage

230V50Hz

Rated current

1A ~ 63A (adjustable), 63A (default)

Under-voltage protection value range

OFF-210V-150V (adjustable), 160V (default)

Over-voltage protection value range

221V-300V-OFF (adjustable), 280V (default)

Recovery delay time

2 ~ 512s   (Default 60s)

Delay time for power-on

2 ~ 255s (Default 2s)

Power consumption

≤2W

Electrical and mechanical lifespan

≥40 thousand times

63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay

III.Product connection diagram
63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
IV.Method of setting parameter
  1. Under normal circumstances, press and hold "Set" for 3 seconds to enter the setting state. Theupper digital tube
    displays "P01" and the lower digital tube displays "280". P01 means that the firstparameter set is the overvoltage
    value, "280" means the default overvoltage value is 280V. press or  key to modify the overvoltage value, modify
    the range 221V ~ 300V ~ OFF; press the set buttonagain, set Overvoltage recovery value, the above digital tube
    displays "P02", the lower digital tubedisplays"250", P02 indicates that the second parameter set is the overvoltage
    recovery value,"250"indicates the default overvoltage recovery value is 250V, press Or  key can modify theover
    -voltage recovery value, modify the range 220V ~ 300V ~ OFF, press the set button again, set theover-voltage
    protection action time, the above digital tube shows "P03", the lower digital tube shows"0.1". P03 means that the
    third parameter set is the overvoltage action time value, "0.1" means thedefault overvoltage action time is 0.1
    second, press or  key to modify the overvoltage actiontime value, the modification range is 0.1~10 seconds;
    default value 0.1 second, it is recommended to≤ 0.1 seconds
  2. Press "Settings" again, the above digital tube displays "P04", and the lower digital tube displays "160". P04 means
    that the fourth parameter set is the undervoltage value, "160" means the defaultundervoltage action value is 160V,
    press  or  key to modify the undervoltage action value, modifythe range OFF~150V~219V; press the set button
    again, Set the undervoltage recovery value. Theabove digital tube displays "P05", the lower digital tube displays
    "180", P05 indicates that the fifthparameter is the undervoltage recovery value, and "180" indicates the default
    undervoltage recoveryvalue is 180V. Press  or  key to modify the undervoltage recovery value. Modify the range
    fromOFF to 151V to 220V; Press the setup button again to set the undervoltage protection action time. Theupper
    digital tube displays "P06" and the lower digital tube displays "0.1". P06 means that the sixthparameter set is the
    undervoltage action time value, "0.1" means the default overvoltage action timeis 0.1 second, press  or  key to
    modify the undervoltage action time value, the modification rangeis 0.1~30 seconds; default value 0.1 second, it is
    recommended to ≤ 0.5 seconds. Note: After the undervoltage operation time is set longer than 0.5 seconds, the
    relay cannot bedriven due to the power failure of the MCU. Therefore, when the setting time is longer than
    0.5seconds, the grid cannot be disconnected when the power is cut off.
  3. Press the set button again , set the current limit parameter.The upper digital tube displays "P07" andthe lower digital
    tube displays "63". P07 means that the seventh parameter set is the overcurrentvalue, "63" means the default
    overcurrent protection value is 63A, press  or  key to modify theovercurrent protection value, modify the range
    1A ~ 63A; press the set button again, set theovercurrent protection action time, the upper digital tube displays "P08",
    and the lower digital tubedisplays "5.0". P08 means that the eighth parameter set is the overcurrent action time value,
    "5.0" means the default overvoltage action time is 5.0 seconds, press  or  key to modify theovercurrent action time
    value, the modification range is 0.1~512 seconds; default value 5.0 seconds. Itis recommended depending on the usage.
  4. Press "Settings" again to set the fault recovery delay time. The above digital tube displays "P09" andthe lower digital
    tube displays "60". P09 indicates that the ninth parameter set is the fault recoverytime value, and "60" indicates that
    the default fault recovery time value is 60 seconds. Press  or to modify the fault recovery time value, and the
    modification range is 2 to 512 seconds.
  5. Press "Settings" again to set the power-on time. The above digital tube displays "P10" and the lowerdigital tube
    displays "2". P10 means that the tenth parameter set is the motor time value at power on, "2" means that the
    default power-on delay time value is 2 seconds, press or  key to modify thepower-on delay time value, modify
    the range 2~ 512 seconds.
  6. Press the setup button again to set the reset mode selection. The upper digital tube displays "P11" and the lower
    digital tube displays "AU". P11 means that the eleventh parameter set is the resetselection mode, "AU" means the
    default fault reset mode is automatic reset, press key to modifythe fault reset mode to "HA" HA means manual reset,
    press  key to select "AU" Switch toautomatic reset mode. When the manual reset mode HA is selected, the protector
    will not resumepower supply after the line fault is recovered. The protector can restore power only when the"Settings"
    button on the protector is manually pressed.
  7. Press the "Settings" button again, the above digital tube displays "P12", and the lower digital tubedisplays "1UL". P12
    indicates that the twelfth parameter set is the most recent fault of the fault query. "1UL" indicates that the last fault is
    an undervoltage fault, UL indicates undervoltage, UH indicatesovervoltage, and IH indicates overcurrent. For example,
    1IH indicates the last time fault is anovercurrent fault. Press the  key to query the last 5 faults.
  8. Press "Settings" again, the above digital tube displays P13, and the lower digital tube displays theword "End". This
    setting is completed. Press the setting button again, the protector saves the data, exits the setting state and enters
    the running state. The above digital tube displays the current voltagevalue, and the lower digital tube displays the
    current current value of the line.
  9. Note: After the user changes the parameters to "Settings", be sure to follow the steps until "END" appears at the end
    and then press "Settings" to save the data, otherwise the modification will beinvalid.
  10. After pressing "Setting", if there is no operation within 10 seconds, the device status will beautomatically exited and
    the changed parameters will not be saved.
  11. Restore factory settings: Press and hold the "" and "" buttons for 3 seconds at the sametime. The lower LED will
    be off and the factory default parameter value will be restored.
  12. Voltage indicator: When the voltage is over voltage, the voltage indicator flashes rapidly. When thevoltage is under
    voltage, the voltage indicator flashes slowly. When the voltage is normal, the voltageindicator is always on.
  13. Current indicator: When the current is over current, the current indicator flashes. When it isnormal, the current
    indicator is always on.
  14. Warranty period mark: During the warranty period, the voltage indicator and current indicator arealways on. After
    the warranty period, the voltage indicator and current indicator are not lit duringnormal state. Only when there is
    abnormal voltage or over current, the voltage indicator or Thecurrent indicator flashes.
V.Normal service conditions and installation environment
  1. The ambient air temperature does not exceed +400C~-50C and the 24-hour average does not exceed+350C.
  2. The relative humidity of the installation site does not exceed 50% when the ambient air temperatureis +400C; it
    can have a higher relative humidity at lower temperatures, for example, when the averageminimum temperature
    of the wettest month is +200C, the month The average maximum relativehumidity is up to 90%. Appropriate
    measures should be taken to prevent condensation due totemperature changes.
  3. The altitude of the installation site should not exceed 2000m.
  4. The protector shall be installed in a medium free of explosion hazard and there shall be no gas orconductive
    dust in the medium sufficient to corrode the metal and destroy the insulation.
  5. The protector should be installed in a place where there is no rain or snow
VI. Announcements 
  1. When performing various operations or tests, the user should follow the relevant procedures andpay attention
    to the following items to ensure correct and safe use.
  2. According to the product identification input and output terminals are correctly wired.
  3. The line conductors shall comply with the relevant current standard values and the load current shallnot exceed
    the maximum protection current value of the protector.
  4. The neutral line N cannot be connected incorrectly and needs to be secure. The protector zero line Nis directly
    connected, and has no disconnection function.
  5. .Before turning on the power, please check the wiring carefully.
  6. Do not touch live parts after the product is connected to the power supply to avoid electric shock.
  7. This protector has no short-circuit protection function and needs to be used with a miniature circuitbreaker. If the
    miniature circuit breaker protection is not used, the short-circuit current cannot bebroken when there is a short
    -circuit fault at the input or output of the protector.
  8. .Since the protector has a self-reset function, after the protector over-current is protected anddisconnected,
    the load electric appliance should be removed immediately, and the circuit line shouldbe checked. Otherwise,
    the protector will frequently turn on the load electrical appliance, andeventually the electrical appliance and the
    protector body will be damaged due to frequent switchingon and off for a long time.
  9. This protector has no isolation function. Please use the miniature circuit breaker when using it, anddisconnect
    the front-end breaker switch when repairing the circuit line.
  10. Please note! When the undervoltage breaking time is greater than 0.3 seconds, theprotector does
    not open after the power failure. (The power failure of the MCU doesnot work after 0.3 seconds of
    power failure)
  11. After the overcurrent exceeds 5 times within the specified time, the protector lockwill not automatically
    restore the power supply. You must manually press the set buttonto unlock the power supply, which can
    effectively protect the device from frequendisconnection caused by not releasing the overcurrent in time.
VII. Different between others
63A 230V DIN Rail Adjustable Over Voltage and Under Voltage Protective Device Protector Relay
VIII.  FAQ

Q: How to confirm the sensors model ?

A. The buyer need to provide the below information :

Voltage  NPN/PNP   NO/NC/NO+NC   Detected object   Detected distanceI

Q: How to adjust the distance of the photoelectric switch ?

A. Clockwise make the detected distance increase and anti-clockwise decrease

Q: If i want to release order, what's the process?

A: Thanks. You can send inquiry to us by Maoyt or send us by email, we will reply within 24hrs.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now