Moulded case circuit breaker/MCCB
Application
NF-CS series Moulded Case Circuit Breaker, a kind of economic breaker, has the features as following, steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC50/60Hz, rated insulation voltage 660V, max. Rated current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency.
NF-CW series Moulded case circuit breaker is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC 50/60Hz, rated insulation voltage 660V, max. Rated current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency.
NF-SS series Moulded case circuit breaker is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC 50/60Hz, rated insulation voltage 660V, max. Rated current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency.
Type |
Pole Number
(P) |
Rated current (A) |
Rated current of frame (A) |
Rated ultimate breaking capacity (KA) |
NF30-CS |
3 |
3, 5, 10, 15, 20, 30 |
30 |
1.5 |
NF50-CS |
2, 3 |
10, 15, 20, 30, 40, 50 |
50 |
5/10 |
NF60-CS |
3 |
60 |
60 |
5/10 |
NF100-CS |
2, 3 |
60, 70, 100 |
100 |
18/25 |
NF250-CS |
3 |
125, 150, 175, 200, 225, 250 |
250 |
18/25 |
NF400-CS |
3 |
250, 300, 350, 400 |
400 |
25/50 |
NF630-CS |
3 |
500, 600, 630 |
630 |
35 |
NF800-CS |
3 |
600, 700, 800 |
800 |
35 |
NF1250-CS |
3 |
800, 1000, 1200, 1250 |
1250 |
85 |
Type |
Pole number |
Rated current(A) |
circuit breaking capacity(KA) |
AC(P1/P2) |
240 |
380 |
415 |
500 |
600 |
660 |
NF30-CW |
2 |
3, 5, 10, 15, 20, 30 |
5/5 |
5/2.5 |
2.5/1.5 |
2.5/1.0 |
|
|
3 |
10, 20, 30, 40, 50 |
NF50-CW |
3 |
10, 20, 30, 40, 50, 60 |
5/10 |
10/7.5 |
7.5/5 |
7.5/5 |
2.5/1.5 |
|
NF60-CW |
3 |
60, 75, 100 |
5/10 |
10/7.5 |
7.5/5 |
7.5/5 |
2.5/1.5 |
|
NF100-CW |
3 |
60, 75, 100 |
50/42 |
30/20 |
7.5/5 |
15/10 |
10/5 |
5/2.5 |
4 |
NF250-CW |
3 |
125, 150, 175, 200, 225, 250 |
50/42 |
30/20 |
7.5/5 |
15/10 |
10/5 |
5/2.5 |
4 |
NF400-CW |
3 |
250, 300, 350, 400 |
85/60 |
50/35 |
25/20 |
35/25 |
25/18 |
15/10 |
4 |
NF630-CW |
3 |
500, 600, 630 |
85/60 |
50/35 |
50/30 |
35/25 |
25/18 |
15/10 |
4 |
NF800-CW |
3 |
600, 700, 800 |
85/60 |
50/35 |
50/30 |
35/25 |
25/18 |
15/10 |
Model |
Pole Number |
Rated current (A) |
(P1/P2)lca/lcs Breaking capccity (KA) |
230 |
400 |
440 |
500 |
NF50-CP |
3 |
5, 10, 15, 20, 30, 40, 50 |
5/2 |
5/2 |
2.5/1 |
2.5/1 |
NF60-CP |
3 |
60 |
5/2 |
5/2 |
2.5/1 |
2.5/1 |
NF100-CP |
3 |
60, 75, 100 |
25/13 |
10/5 |
10/5 |
7/4 |
NF250-CP |
3 |
125, 150, 175, 200, 225, 250 |
30/15 |
18/9 |
15/8 |
10/5 |
NF400-CP |
3 |
250, 300, 350, 400 |
50/25 |
36/18 |
25/13 |
15/8 |