Product Description
RS-75W Switching Power Supply
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105º C long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70º C
Withstand 5G vibration test
High efficiency, long life and high reliability
75W Mini Switching Power Supply RS-75 |
MODEL |
RS-75-3.3 |
RS-75-5 |
RS-75-12 |
RS-75-15 |
RS-75-24 |
RS-75-48 |
DC VOLTAGE |
3.3V |
5V |
12V |
15V |
24V |
48V |
RATED CURRENT |
15A |
12A |
6A |
5A |
3.2A |
1.6A |
CURRENT RANGE |
0 ~ 15A |
0 ~ 12A |
0 ~ 6A |
0 ~ 5A |
0 ~3.2A |
0 ~ 1.6A |
RATED POWER |
49.5W |
60W |
72W |
75W |
76.8W |
76.8W |
RIPPLE & NOISE (max.) |
80mVp-p |
80mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
200mVp-p |
VOLTAGE ADJ. RANGE |
3.2 ~ 3.6V |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
22 ~ 27.6V |
42 ~ 54V |
VOLTAGE TOLERANCE |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
SETUP, RISE, HOLD TIME |
500ms, 30ms, 60ms/230VAC, 500ms, 30ms, 14ms/115VACat full load |
VOLTAGE RANGE |
88 ~ 264VAC 125 ~ 373VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
71% |
76% |
81% |
82% |
85% |
86% |
AC CURRENT(Typ.) |
2A/115VAC 1.2A/230VAC |
INRUSH CURRENT (Typ.) |
COLD START 40A/230VAC |
LEAKAGE CURRENT |
<2mA / 240VAC |
OVERLOAD |
110 ~ 150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE |
3.8 ~ 4.45V |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
55.2~ 64.8V |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
WORKING TEMP. |
-25 ~ +70ºC (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-40 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes |
SAFETY STANDARDS |
Design refer to UL60950-1,TUV EN60950-1 |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION |
Compliance to EN55022(CISPR22) Class B |
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A |
MTBF |
265Khrs min. MIL-HDBK-217F (25ºC) |
DIMENSION |
129*97*38mm (L*W*H) |
PACKING |
0.41Kg; 30pcs/13.3Kg/0.86CUFT |