Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL |
DR-100-12 |
DR-100-15 |
DR-100-24 |
|
OUTPUT
|
DC VOLTAGE |
12V |
15V |
24V |
RATED CURRENT |
8.3A |
6.5A |
4.2A |
|
CURRENT RANGE |
0 - 8.3A |
0 - 6.5A |
0-4.2A |
|
RATED POWER |
100W |
100W |
100.8W |
|
RIPPLE & NOISE (max.) |
120mVp-p |
120mVp-p |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
12- 15V |
15-18V |
24 - 29V |
|
VOLTAGE TOLERANCE |
±2.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
2700ms, 80ms/230VAC 2700ms, 80ms/115VAC at full load |
|||
HOLD UP TIME (Typ.) |
50ms/230VAC 18ms/115VAC at full load |
|||
INPUT
|
VOLTAGE RANGE |
88 ~ 264VAC 124 - 370VDC [DC input operation possible by connecting AC/L(+),AC/N(-)] |
||
FREQUENCY RANGE |
47 - 63Hz |
|||
EFFICIENCY (Typ.) |
87% |
87% |
89% |
|
AC CURRENT (Typ.) |
3A/115VAC 1.6A/230VAC |
|||
INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 45A/230VAC |
|||
PROTECTION
|
OVERLOAD Note.6 |
105 -135% rated output power |
||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||||
OVERVOLTAGE |
16 ~ 20V |
19 -23V |
30 -35V |
|
Protection type: Shut down o/p voltage, re-power on to recover |
||||
OVER TEMPERATURE |
Shut down o/p voltage, re-power on to recover |
|||
ENVIRONMENT
|
WORKING TEMP. |
-20 - +60"C (Refer to "Derating Curve") |
||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||
STORAGE TEMP., HUMIDITY |
-40 - +85 °C, 10 ~ 95% RH |
|||
TEMP. COEFFICIENT |
±0.03%/oC(0~50°C) |
|||
VIBRATION |
Component:10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||
OTHERS
|
MTBF |
486K hrs min. MIL-HDBK-217F (25°C) |
||
DIMENSION |
100*93*56mm (W*H*D) |
|||
PACKING |
0.35Kg; 35pcs/16.5Kg/0.89CUFT |