MODEL |
NFM-05-15 |
|
OUTPUT |
DC VOLTAGE |
15V |
RATED CURRENT |
0.33A |
|
CURRENT RANGE |
0 ~ 0.33A |
|
RATED POWER |
4.95W |
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
13.5 ~ 16.5V |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
|
LINE REGULATION |
±0.5% |
|
LOAD REGULATION |
±0.5% |
|
SETUP, RISE TIME |
1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load |
|
HOLD UP TIME (Typ.) |
100ms/230VAC 24ms/115VAC at full load |
|
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 440Hz |
|
EFFICIENCY (Typ.) |
74% |
|
AC CURRENT (Typ.) |
0.12A/115VAC 0.08A/230VAC |
|
INRUSH CURRENT(Typ.) |
COLD START 25A/115VAC 45A/230VAC |
|
LEAKAGE CURRENT Note.5 |
Touch current < 80µ A/264VAC |
|
PROTECTION |
OVERLOAD |
Above 105% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
OVER VOLTAGE |
17.25 ~ 20.25V |
|
Protection type : Shut off o/p voltage, clamping by zener diode |
||
OVER TEMPERATURE Note.5 |
Tj 145°C typically (U1) detect on main control IC |
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70°C (Refer to Derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40 ~ +85°C , 10 ~ 95% RH |
|
TEMP. COEFFICIENT |
±0.03%/°C (0~50°C) |
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
|
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved |
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P: 100M Ohms / 500VDC / 25°C/ 70% RH |
|
EMC EMISSION |
Compliance to EN55011(CISPR11) ,EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A |
|
OTHERS |
MTBF |
738.7Khrs min. MIL-HDBK-217F (25°C ) |
DIMENSION |
58*45*19.1mm (L*W*H) |
|
PACKING |
0.03Kg; 120pcs/4.6Kg/0.97CUFT |
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directive. 5. The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification provided by the IC manufacturer. 6. Touch current was measured from primary input to DC output. 7. Suitable for BF application with appropriate system consideration |
1. Prompt reply: Any inquiry or questions would be replied within 24 hours. |
2. Quality Product: Manufacture company, each of the products is tested and calibrated. |
3. Hospitality: Offer smiling service and your visiting is highly welcomed |
4. Fast delivery: delivery time is within 3-7 days usually, other occasion depends on the order qty. |
Trade Terms | FOB ,CIF ,CFR,EXW,DDP |
Payment terms | T/T,L/C,Western union,Paypal,Escrow,MoneyGram |
Payment conditions | 30% deposit in advance,70% balance before shipping. |
Delivery time | 3-7working days after deposit,2-4 working days for inventory |
Packing | Neutral carton,Wooden case for large size |
Shipping | By sea,by air and by express delivery |
Payment conditions | 30% deposit in advance,70% balance before shipping. |
Delivery time | 3-7working days after deposit,2-4 working days for inventory |
Packing | Neutral carton,Wooden case for large size |
Shipping | By sea,by air and by express delivery |