| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

• Factory control or automation apparatus
• Test and measurement instrument
• Laser related machine
• Burn-in facility
• RF application
|
Model number
|
RSP-1000-24
|
RSP-1000-36
|
RSP-1000-48
|
RSP-1000-60
|
RSP-1000-72
|
RSP-1000-110
|
RSP-1000-150
|
|
DC output voltage
|
24V
|
36V
|
48V
|
60V
|
72V
|
110V
|
150V
|
|
Rated output current
|
41.7A
|
27.8A
|
20.8A
|
16.7A
|
14A
|
9.1A
|
6.7A
|
|
Rated output power
|
1000W
|
1000W
|
1000W
|
1002W
|
1008W
|
1001W
|
1005W
|
|
Efficiency (at full load)
|
88.3%
|
88.7%
|
89.5%
|
89.7%
|
90%
|
90%
|
91%
|
|
Voltage regulation range
|
17-25V
|
25-36V
|
33-48V
|
41-60V
|
50-74V
|
74-110V
|
102-150V
|
|
|
Equipped with active PFC power factor correction function
|
||||||
|
Input voltage
|
Communication: 110 - 240V (Wide voltage automatic adaptation, no need for switching)
|
||||||
|
Power factor (PF value)
|
PF value: 20.997/110VAC (at 100% full load)
|
||||||
|
|
PF value: 20.993/220VAC (at 100% full load)
|
||||||
|
Fan shutdown protection
|
Either of the two cooling fans is not rotating or the fan is not detected. The power supply has no output voltage and the machine does not start.
|
||||||
|
Output overload protection
|
The overload protection mode is a constant current limiting mode. The output current value is locked and does not increase.
|
||||||
|
Overheat protection
|
When the internal temperature of the power supply is too high, the overheating protection is activated, the output voltage is shut off, and the temperature drops.
|
||||||
|
Output short-circuit protection
|
Short-term instantaneous short circuit: Power off, and it will automatically recover after 3 seconds.
|
||||||
|
|
Long-term continuous short circuit: Power off. Every 3 seconds, it will automatically restart once (burp mode)
|
||||||
|
Output overvoltage protection
|
The overvoltage point is 130% of the nominal voltage. After overvoltage, the protection lock is activated and will not
automatically recover. It needs to be powered off and then powered on again to restore. |
||||||
|
Input under-voltage protection
|
If the AC input voltage is lower than 96V, the power supply cannot be used.
|
||||||
|
Heat dissipation method
|
Temperature-controlled automatic speed-regulating fan (blows inward, with 2 fans)
|
||||||
|
Weight
|
1.4 kg (excluding accessories and packaging)
|
||||||
|
Case size
|
265*131*41mm
|
||||||




