Type: SPD Surge Protective Device
Structure: Protective Gap
Installation: DIN Rail
Application: AC/DC System
Size: Small
Operation Voltage: Low Voltage
Samples:
US$ 3.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
SPD LY1-D LY1-C LY1-B
Shape
DIN Rail
Material
Plastic
Certification
CE
Brand
Winston
Breaking Capacity
High Voltage Circuit Breakers
Operation
Electric Type
Speed
High-Speed Circuit Breaker
Function
Surge Protection Device
Antistop
Surge Protection
Transport Package
Export Standard Carton Box
Specification
CE
Trademark
Winston/OEM/Neutral
Origin
China
HS Code
8536411000
Production Capacity
10000PCS/Day

Product Description

LY1 SPD Surge protective device/Power Surge Protective Device / voltage surge protective device / surge protection device /SPD Single phase and three phase

1. Product Description:

LY1- C Series surge protective device SPD is suitable for TN-S, TN-C-S, TT, IT ect. Power supply system of AC 50/60Hz, <=380V, installed on the joing of LPZ1 or LPZ2 and LPZ3, It's designed according to IEC61643-1, GB18802.1, It apots 35mm standard rail, their is a failure release mounted on the module of surge protective device. When the SPD fails in breakdown for over-heat and over-current, the failure release will help electric device separate from the power system and give the indication signal, green means normal, red means abnomarl, it is also could be replaced for the module when has operating voltage.

2. Product Features:

A. Could be replaced for the module no need power cut

B. Maxi current of endure the surge stroke 40KA (8/20us)

C. Time of response<25ns

D. The color of visible window shows operating status, green means normal, red means abnormal


 

Specification:
  

Model
LY1-D
   Technical Parameters
Rate Operating Voltage Uc(V~) 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc(V~) 275V 385V 320V 385V
Voltage Protection Level Up(V~)kA ≤0.7 ≤1.0 ≤1.2 ≤1.5
Nominal Discharge Current In(8/μ20μs)kA 5 10
Maximum Discharge Current Imax(8/μ20μs)kA 10 20
Response Time ns <25
Test Standard GB18802.1\IEC61643-1
L/N(mm2)The Cross Section of L/N Line 6
PE(mm2)The Cross Section of PE Line  16
Fuse or Switch(A) 10A,16A 16A,25A
Operating Environment°C -40°C~+85°C
Relative Humidity(25°C) ≤95%
Installation Standard Rail 35mm
Material Of Outer Covering Fiber glass reinforced plastic
 
 
 
Technical parameters LY1-C N-PE
Rated operating voltage Un 110V 220V 380V 220V 380V 220V 380V
Max continuous operating voltage Uc 140V 275V 320V 385V 420V 440V 275V 320V 385V 420V 440V 255V
Voltage protection level Up <=0.8 <=1.2 <=1.5 <=1.8 <=2.0 <=1.2 <=1.0 <=1.4 <=1.5 <=1.8 <=2.0 <=1.0/<=1.0/<=1.8
Normal discharge current In 20kA 15kA 5kA/12.5kA/25kA
Max discharge current Imax 40kA 30kA
Response time <25ns 100ns
Test standard GB18802,IEC61643-1
The cross section of L/N line 10,16mm2 10mm2  
The cross section of PE line 10,25mm2 16mm2  
Fuse or Switch 32A 25A,32A  
Operating environment -40~+85 degrees
Relative humidity <=95%
Installation Standard rail 35mm
Material of outer covering Fiber glass reinforced plastic
 
Technical parameters LY1-B
Rated operating voltage Un 220V 380V 220V 380V 220V 380V
Max continuous operating voltage Uc 385V 420V 385V 420V 385V 420V
Voltage protection level Up <=2.8 <=3.2 <=2.2 <=2.5 <=2.0 <=2.3
Normal discharge current In 60kA 40kA 30kA
Max discharge current Imax 100kA 80kA 60kA
Response time <25ns
Test standard GB18802,IEC61643-1
The cross section of L/N line 16,25mm2 10,16mm2 10,16mm2
The cross section of PE line 25,35mm2 25mm2 16,25mm2
Fuse or Switch 63,100A 63A 32,63A
Operating environment -40~+85 degrees
Relative humidity <=95%
Installation Standard rail 35mm
Material of outer covering Fiber glass reinforced plastic

 

 

CE Single Phase Electric SPD 1p 2p 3p 4p Npe 20ka 40ka 100ka Surge Protective DeviceCE Single Phase Electric SPD 1p 2p 3p 4p Npe 20ka 40ka 100ka Surge Protective DeviceCE Single Phase Electric SPD 1p 2p 3p 4p Npe 20ka 40ka 100ka Surge Protective Device
Why choose us?
 
1.Professional manufacture
2.With complete varieties
3.Accept OEM
4.We have completely sales service system, ensure every detail is going smooth
5.We have new designed products each year by our R&D Department
6.Perfect testing system ensure each product is qualified

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now