| Customization: | Available |
|---|---|
| Application: | High Frequency Converter Transducer |
| Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

|
Permanent magnet asynchronous integrated program
|
380V, full power range coverage
|
|
Excellent structural compatibility
|
Compatible with WSTG800 structure
|
|
High-carrier frequency
|
Up to 16kHz
|
|
Multiple communication modes
|
485, simple Can bus
|
|
Excellent high-speed permanent magnet drive capability
|
Speed tracking function of high-speed permanent magnet motor
|
|
Max. frequency
|
Vector control: 0.00~1500.00Hz V/f control: 0.00~650.00Hz
|
|
Carrier frequency
|
0.8kHz~16kHz, which can automatically be adjusted according to load characteristics
|
|
Input frequency resolution
|
Digital setting: 0.01Hz
Analog setting: max. frequency x 0.025%
|
|
Control mode
|
Open-loop vector control (SVC) Closed-loop vector control (FVC) V/f control
|
|
Starting torque
|
G-type: 0.25Hz/150%(SVC),0Hz/180%(FVC)C)
|
|
Speed regulation range
|
1:200 (SVC) 1:1000(FVC)
|
|
Steady speed accuracy
|
±0.5%(SV C) +0.02%(FVC)
|
|
Torque control accuracy
|
±5%(SV C)(above 5Hz) +3%(FVC)
|
|
Overload capacity
|
G-type: 150% rated current for 60s
|
|
Torque boost
|
Automatic torque boost, manual torque boost 0.1%~30.0%
|
|
V/f curve
|
Four methods: linear, multi-point, complete V/f separation; incomplete V/f separation
|
|
V/f separation
|
2 methods: complete separation, partial separation
|
|
Acceleration /deceleration curves
|
Linear or S-curve acceleration/deceleration mode.
Four acceleration / deceleration times; Acceleration /deceleration time range:
0.0s~6500.0s |
|
DC braking
|
DC braking freguency: 0.00Hz max. frequency
Braking time: 0.0s 36.0s
Braking action current: 0.0%100.0%
|
|
Inching control
|
Inching freguency range: 0.00Hz~50.00Hz
Inching acceleration/deceleration time:0.0s ~6500.0s
|
|
Simple PLC, multi-speed operation
|
Up to 16-speed operation through built-in PLC or control terminals
|
|
Built-in PiD
|
Easy to achieve process control and closed-loop control systems
|
|
Automatic voltage regulation (AVR)
|
The output voltage can be kept constant automatically when the grid voltage changes
|
|
Overvoltage / overcurrent stall control
|
The current / voltage can be limited automatically during operation to prevent frequent overcurrent / overvoltage tripping
|
|
Quick current limiting function
|
Overcurrent faults can be minimized to ensure the normal operation of frequency converters
|