Electricity Type: | DC |
---|---|
Number of Pole: | 1 |
Phase: | 1 |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
• 125A Contact switching capability
• It has a set of normally open contacts
• Coil power consumption:7~16W Min~Max
• Application scope:Wind energy,Photovoltaic,Telecommunication
and Communication equipment,Engineering machinery,Battery car,
Electric forklift,Train electrical,Control systems such as ships and
uninterruptible power supply
• Technical specifications:GB/T14048.4-2020
• Product compliance: ROHS
• Product certification: CCC CE
Model
|
WSW-80/o
|
Contact form
|
1D (SPST-NO)
|
Contact material
|
Silver alloy
|
Contact load
|
125A×60VDC(DC-1)
|
Contact pressure drop
|
≤80mV@125A
|
Insulation resistance
|
Min. 100MΩ at 500VDC
|
Dielectric Strength
|
1000VAC 50 HZ/60 HZ (1 minute) Leakage current less than 1mA
|
Pulse width
|
/ ( Only applicable to WSW80M series )
|
Pull in time
|
Max. 30mSec.
|
Release time
|
Max. 30mSec.
|
Pull-in voltage (DC V)
|
≤70% US
|
Release voltage (DC V)
|
≥10% US
|
Operating ambient temperature
|
-25ºC~+60ºC
|
Storage temperature
|
-40ºC~+65ºC
|
Relative humidity
|
20%~90% RH
|
Mechanical life
|
≥150,000 second
|
Auxiliary switch
|
5A/24V DC;2A/48V DC
|
Minimum load of auxiliary contact
|
100mA/5V
|
Class of pollution
|
III
|
Working system
|
Continuous working system
|
Vibration
|
(10~200)Hz acceleration ≤3.5g
|
To attack
|
(60) Times / minute acceleration 6g
|
Model
|
Coil voltage (V)
|
Coil operating voltage(V)
|
Pull-in voltage(V)
|
Release voltage(V)
|
Starting current(A)
|
Power waste(W)
|
WSW-80/O
|
12
|
0.85US~1.1US
|
≤70%
|
≥10%
|
≤1
|
7~16
|
24
|
≤0.6
|
7~16
|
||||
36
|
≤0.5
|
7~16
|
||||
48
|
≤0.3
|
7~16
|
||||
60
|
≤0.25
|
7~16
|
||||
72
|
≤0.2
|
7~16
|
1.When installing the contactor, the tightening torque of the main circuit wiring screw nut is 8~10N.m;
Control circuit wiring screw nut tightening torque 1~1.5N.m.
2.The driving circuit power of the product coil must be greater than or equal to the product coil power,
Otherwise the cutting capacity of the product will be reduced.
3.The voltage continuously applied to the coil shall not exceed the maximum allowable voltage.
Otherwise, the abnormal heating of the coil will shorten the life of the insulation layer.